Specification:-

  • Open Care Systems Allow To Efficiently Care And Provide Advance Warming Capabilities While Using One Touch Operations To Simplify Procedures. Advance Microprocessor Controlled System With Self Check On The Electronic Circuit Skin / Air Manual Control.
  • Control Panel
  • The Open Care System Comes Complete With Automatic Manual And Baby (Servo) Modes.
  • The Skin / Air Temperature Display Is Larger Than Other Set Temperature Display. Skin Temperature Display Can Be Converted Form °C To °F By The Push Of A Button. A Big LCD Is Provided For More Information And Visualizations Of The Heater Power In Manual And Servo Modes. 
  • A Full Set Of Alarms Provides Safety And Convenience, With Both Audible And Visual Indicators In The Event Of :

• High Temp. / Low Temp. • System Fail • Probe Failure • Power Failure • Timer • Heater Only Visual Alarm Provided

  • Heater Assembly
  • The Heater Assembly Located Above The Centre Of The Support Structure Consists Of An Integral Examination Light And A 650 Watts Heating System (Silica Or Quartz / Ceramic Heater) For Quick Warming And Even Distribution Of Heat On The Baby Bed. The Heater Can Be Swivel Led In Either Direction For Taking X-Ray And Doing Procedures.
  • Manual Mode
  • The System Automatically Starts Heating From 40% In Manual Mode And The Same Can Be Changed Through Settings Upto 100%. The System Automatically Converts From Servo Mode To Manual Mode In Case Of Probe Failure Thus Providing Non Stop Working Of The Unit.
  • Baby Bed
  • The Spacious Baby Bed Incorporates Easy Drop Down / Fold Down Glasses For Maximum Access To The Patient.
  • The Neonate Can Be Supplied With A Constant Oxygen Flow Through The Oxygen Humidifier When Connected To An Oxygen Cylinder / Wall Unit. The Motorized Slow Suction Can Be Used With A Simple Flip Of A Switch. A Digital Apgar Time Is Standard, Which Signals When 1 ,5 And 10 Minutes Have Elapsed.
  • The System Is Fitted With High Quality Castors Having Brakes In Front 2 Castors. Antistatic Castors
  • The Unit Comes Fitted With Two Drawer System Which Slides Out For Keeping Consumables.
  • If Needed The Unit Can Be Programmed By The User Him Self For Any Of The Following Features :
  • (a) Count Up / Down Timer.
  • (b) Check Baby Alarm.
  • (c) Pre Warming Mode.

Write a review