Menu
Your Cart
Winter Sale Offer on ULV Foggers , till 28th Feb 2024

Wellton Healthcare Radio Frequency Cautery WH-1975

Wellton Healthcare Radio Frequency Cautery WH-1975
Wellton Healthcare Radio Frequency Cautery WH-1975
Rs29,500.00
Ex Tax: Rs25,000.00
  • Stock: 100
  • Model: WH-1975

Enter Pincode for delivery

Wellton Healthcare Radio Frequency Cautery WH-1975

Specification :-

  • Radio Frequency Cautery Is Used As High-Frequency Electrical Current That Can Be Used As Either Bipolar Or Monopolar Mode (4.0 mHz). The Zone Of Injury Is Comparable Or Less Than A Carbon Dioxide Laser When Both Are Used In Appropriate Fashion For Traditional Surgery
  • Radio Frequency Cautery Involves The Passage Of High Frequency Radio Waves(2mhz-Megahertz) Through Soft Tissue To Cut, Coagulate Or Remove The Tissue. Soft Tissue Resistance To These Radio Waves Causes The Cellular Water In The Soft Tissue To Heat, Which Produces Steam, An Results In Cellular Molecular Dissolution Of Individual Tissue Cells.
  • The Surgeon Uses A Hand Piece With An Active Electrode (Different Type Of Electrodes For Different Applications) To Transmit The Radio Waves. The Radio Waves Are Focussed On The Tissue By An Antenna Plate (Patient Plate) That Is Positioned Behind The Tissue In Contact With Patient's Skin.
  • Radio Surgery In General Practise Has Many Advantages Over Conventional Surgical Techniques Particularly Dermatological, Plastic And Eye Lid Surgery, ENT ,Dental,Quicker Operating Time,Rapid Healing,Less Tissue Damage And Less Post Operative Discomfort .
  • Radio Frequency Cautery Is Not To Be Confused With Electro-Surgery Machine(Surgical Diathermy) Spark Gap Circuitry Unit(Electro Cautery Machine) And Uses Completely New Technique Compared With Scalpal Surgery And Other Techniques And Radio Energy Does The Cutting Very Light. 
  • A Very High Frequency Radio Wave 0.3 - 2 MHz And A ine Needle Or Wire Loop Electrode Which Is Held By The Surgeon, Radio Energy Passes Between The Cautery Electrode And Patient Plate. It Is Concentrated At The Needle End Or Wire Loop Electrode, Resulting In The Release Of Energy, Which Produces Steam Within The Cells, Thus Vaporizing Them And  Dividing The Tissues.
  • Power Input 220 Volts +-5%
  • Power Consumption 150 Watts
  • Frequency 2 MHz
  • Maximum Output
  • HF Monopolar 150 Watts On 400 ohm Load
  • HF Bipolar 100 Watts On 100 ohm Load
  • Fulguration 100 Watts On 1000 ohm.
  • Size: 8 1/2" X 7 1/2" X 4"
  • Weight: 3.5 Kgs



Write a review

Note: HTML is not translated!
Bad Good